Achizitionati un aparat de aer conditionat Daikin si primiti GRATUIT extinderea garantiei cu 2 ani. Vezi detalii.

FWF-B

Unitate de Caseta

Unitate AC destinata instalarii in tavan. Posibilitate de a inchide 1 sau 2 clapete de refulare

- Dotata cu panou alb decorativ modern (RAL 9010);
- Carcasa compacta cu dimensiuni standard ce permite ca unitatea sa fie montata in plafon fara a fi nevoie de ajustarea modulelor decortive;
- Functia de autobaleiere orizontala aduce confort, nu permite formarea curentilor de aer si previne patarea tavanului;
- Priza de aer proaspat ce este inclusa in unitate ofera economie la instalare nefiind necesara debitarea unei aerisiri suplimentare;
- Dotare standard cu pompa de condens cu inaltimea de evacuare de 750 mm.
FWF-B cassette unit02
La comanda
03
La comanda
04
La comanda
05
La comanda
FWF**BT, 2 pipe unit, incl. condensate pump, without valves Lei (TVA inclus)2658283329933147
Capacitatea de racire (Total at Super Hight Speed) kW2.003.204.205.20
Capacitatea de incalzire (2- pipe at Super High Speed) kW2.904.005.406.70
FWF**BF, 4 pipe unit, incl. condensate pump, without valves Lei (TVA inclus)2890309032283363
Capacitatea de racire (Total at Super Hight Speed) kW2.002.703.504.50
Capacitatea de incalzire (4- pipe at Super High Speed) kW3.803.804.906.10
Vizualizeaza si descarca fisa tehnica a produsului PDF Fisa tehnica unitate interioara
Note: Decoration panel is mandator, it is included with other accessories in table.
Options02
La comanda
03
La comanda
04
La comanda
05
La comanda
Decoratio panel 4-way blowBYFQ60B3
Lei (TVA inclus)1101
Sealing member of air discharge outletKDBH44BA60
Lei (TVA inclus)551
Long-life filterKAFQ441BA60
Lei (TVA inclus)la cerere
Panel spacerKDBQ44B60
Lei (TVA inclus)2090
Fresh air intake kitKDDQ44XA60
Lei (TVA inclus)688
Control system02
La comanda
03
La comanda
04
La comanda
05
La comanda
Remote control infrared H/ PBRC7E530 (11)
Lei (TVA inclus)769
Remote control infrared C/ OBRC7E531 (11)
Lei (TVA inclus)1230
Remote control wiredBRC315D (1)
Lei (TVA inclus)473
Central remote controlDCS302C51 (2)
Lei (TVA inclus)7435
Electrical box with earth terminal (3 blocks)KJB311A
Lei (TVA inclus)338
Unified on/ off controlDCS301B51 (5)
Lei (TVA inclus)3122
Electrical box with earth terminal (2 blocks)KJB212A
Lei (TVA inclus)324
Shedule timerDST301B51 (5) (8)
Lei (TVA inclus)3913
Wiring adapter for electrical appendices 1KRP2A52 (4) (8)
Lei (TVA inclus)1439
Wiring adapter for electrical appendices 2KRP4A53 (4) (8)
Lei (TVA inclus)745
Installation box for adapter PCBKRP1BA101 (9)
Lei (TVA inclus)295
Remote sensorKRCS01-1
Lei (TVA inclus)366
Intelligent touch controllerDCS601C51 (3) (7)
Lei (TVA inclus)8772
Electrical installation boxKJB411A
Lei (TVA inclus)580
Optional PCB for MOD-bus connectionEKFCMBCB (4) (8)
Lei (TVA inclus)387
2-way valve - on/offEKMV2C09B (4) (6) (10)
Lei (TVA inclus)326
3-way valve - on/offEKMV3C09B (4) (6) (10)
Lei (TVA inclus)367
Valve control PCBEKRP1C11
Lei (TVA inclus)345
Remote 'on/off' and 'forces off' kitEKRORO (12)
Lei (TVA inclus)111
Notes:

1. Optional, electrical installation box with earth terminal KJB212A is required, if controllere wires need to be installed in the wall.
2. Requires electrical installation box with earth terminal KJB311A.
3. Requires electrical installation box KJB411A.
4. Requires installation box KRP1H98 for FWC-B and KRP1BA101 for FWF-B.
5. Requires electrical installation box with earth terminal KJB212A, if built in the wall.
6. Requires valve control PCB EKRP1C11.
7. I-touch:
• Not allowed to use the i-touch for an installation with both fan coils and VRV units.
• Can not be used in combination with fan coil units, that use MOD bus communication.
• No Airnet or telephone connection possible.
8. Only 1 of these 4 options can be installed on 1 indoor unit.
9. FWC-B: Max. 1 KRP1H98 box can be mounted on the unit.
Max. 2 PCB's can be mounted in 1 KRP1H98 box.
FWF-B: Max. 2 KRP1BA101 boxes can be mountd on the unit.
Max. 1 PCB can be mounted in 1 KRP1BA101 box.
10. FWC-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11.
FWC-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11.
FWF-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11.
FWF-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11.
11. It is possible to change the operation mode, but this will not have an impact on the water temperature.
(No feed back to water souce)
It is not possible to select the 'auto air flow' setting.
Dry operation can be selected with this remote control, but this function is not available on the FWC-B / FWF-B model.
12. This option is needed to create T1 T2 wire.

All options are supplied as kit.
Vizualizeaza si descarca
Poti alege sa schimbi limba materialelor:
Manual operare / instalare PDF
Schema circuit electric / frigorific PDF
Desene dimensionale / Nivel presiune sonora PDF
Catalog prezentare PDF
Va stam la dispozitie cu mai multe variante prin care ne puteti contacta, urmand ca dumneavoastra sa o alegeti pe aceea pe care o considerati convenabila.
Telefonic cu specialistul Daikin ales din departamentul dorit - vanzari sau service.
Departament vanzari
Razvan
0755 054 410
Departament service
Program
Luni-Vineri
900 - 1800

Sambata
900 - 1300
Ne trimiteti un e-mail sau completati formularul de mai jos si va contactam noi telefonic.
Adresa e-mail
Formular

Completand acest formular sunteti de acord cu termenii GDPR.
In cel mai placut mod in urma unei vizite in showroomul nostru din Bucuresti.
Adresa
Bucuresti, Romania
Toate drepturile rezervate Bueno Tech SRL® 2023 | Termeni si conditii | GDPR | Abonare RSS | Ultima actualizare: 04-10-2023
Bueno Tech si logo-ul Bueno Tech sunt marci inregistrate aflate in proprietatea Bueno Tech SRL, iar folosirea lor fara un acord scris intra sub incidenta legii.